4 of 6 D5 Data Sheet
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Impact D5
Dairy & Delicatessen
Electrical Data
Number of Fans 8 ft 12 ft
Refrigeration – 9W 2 3
Export – 9W 2 3
Amperes Watts
Merchandiser 8 ft 12 ft 8 ft 12 ft
Fans (Refrigeration)
Standard (120V 60Hz) 1.40 2.10 105 160
Energy Efficient (120V 60Hz) 0.76 1.14 50 75
Export (230V 50Hz) 0.76 1.14 114 171
Constant On Anti-sweat Heaters NA NA NA NA
Cycling Anti-sweat Heaters NA NA NA NA
Minimum Circuit Ampacity
With Standard Fans (120V 60Hz) 1.60 2.30
With Energy Efficient Fans (120V 60Hz) 0.96 1.34
With Export Fans (230V 50Hz) 0.96 1.34
Maximum Over Current Protection 120V 20 20
Export (230V 50Hz) 15 15
Electric Defrost Heaters (208V 1
ΦΦ
) NA NA NA NA
Gas Defrost Heaters (208V) NA NA NA NA
Standard Lighting 8 ft 12 ft 8 ft 12 ft
1 Row Canopy 0.51 0.77 59 85
Optional Lighting
1 Row Canopy and 1 Row Rail 1.02 1.54 118 170
2 Rows Canopy 1.02 1.54 118 170
2 Rows Canopy and 1 Row Rail 1.53 2.31 177 255
Optional Shelf Lighting
1 Row Shelves 0.51 0.77 59 85
2 Rows of Shelves 1.02 1.54 118 170
3 Rows of Shelves 1.53 2.31 177 255
4 Rows of Shelves 2.04 3.08 236 340