40 tEchnIcal data
P/N 3034041_D U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
Electrical Data
DEFROST DATA
Frequency (hr) 12
OFF-TIME DEFROST
PHYSICAL DATA
Refrigerant Charge (R290)
(0.150 kg each system)
VRM1B 5.3 oz 0.150 kg (1 system)
VRM2B 5.3 oz 0.150 kg (1 system)
VRM3B 5.3 oz 0.150 kg (1 system)
Note: This data is based on store temperature
and humidity that does not exceed 80°F and
55% R.H. unless otherwise stated. Schedule
defrost at night while lights are off.
Evaporator Fans
VRM1B VRM2B
Number of Motors
1
2
Amperes
0.13
0.26
Watts
16
32
Compressor LRA 14.9 14.9
Compressor RLA 2.85 2.85
VRM3B
2
0.26
32
14.9
2.85