8
EDS 3000 Operating Manual
PN#02080105 • ELC1603-1752 / 09.16
ELECTRONICS
• Use the “mode” key to call up other parameters, if required, and alter the setting using
the
and the
keys.
• If no keys are pressed for 3 seconds, the display changes back and the settings are
saved.
Note:
• If “LOC” appears in the display when trying to alter the settings, programming
is disabled. Corrective action: set programming enable(s) to “FREE”
(see point 7 “Programming enables”)
• If the
or
keys are held down during alteration, the value
automatically advances.
• If a setting has been altered, “PROG” appears briefly in the display when the
display is switched over. The new setting is then saved in the unit.
5.4 Setting ranges for the switching outputs
Measuring range
in psi
Switching point or
upper switching
value in psi*
Hysteresis or lower
switching value in
psi*
Increment in psi
0 to 15 0.25 to 15.00 0.10 to 14.85 0.05
0 to 30 0.45 to 30.00 0.15 to 29.70 0.05
0 to 50 0.8 to 50.00 0.3 to 79.5 0.1
-14 to 75 -12.6 to 75.0 0.6 to 74.0 0.2
0 to 150 2.5 to 150.0 1.0 to 148.5 0.5
0 to 250 4.0 to 250.0 1.5 to 247.5 0.5
0 to 500 8 to 500 3 to 495 1
0 to 1000 16 to 1000 6 to 990 2
0 to 3000 45 to 3000 15 to 2970 5
0 to 6000 90 to 6000 30 to 5940 10
0 to 9000 140 to 9000 60 to 8900 20
*All ranges given in the table are adjustable by the increments shown.