Performing Maintenance
FAM 25/45/60/75/95
en(us)
Page 80/160
BEWA FAM25-95 3402054f en(us) 2013-06-13 2013-06-13
Performing Maintenance
Maintenance intervals
The inspection and maintenance works listed here are necessary conditions for
ensuring both long service life and error-free operation of the FAM.
In addition, you will find further information in the operating manuals published by
the manufacturers of the components which are supplied with the FAM.
See page
24 hours /
daily
500 hours /
monthly
3000 hours /
every six months
6000 hours /
annually
FAM
Check the FAM for any leaks (visual
check).
- X
Check the screwed fittings to see that
they have been properly resecured.
- X
Inspection of the measurement
technics /
Pressure sensor in the vacuum column
/
Differential pressure manometer at the
fluid filter /
AquaSensor at the IN port /
ETS at the vacuum column (optional)
- X
Check the fault indicator lamps /
perform a lamp test
83 X
Change Air filter 83 X
Cleaning the suction filter 84 X
Water ring vacuum pump
Check and Clean the Level Switch 87 X
Replace water 88 X
Replace water filter vacuum pump 88 X
Cleaning the Cooling Fins on the
Water cooler
89 X
Flushing and completely cleaning the
vacuum pump
89 X