15.0 Basic Trouble Shooting Chart For The Hydro-Temp System
2. Condensate from water coil or
accumulator.
3. Condensation pan not draining.
3. Check for algae. Blow out
restriction in condensate pipe.
4. Check for dirty air filter or
restriction in ductwork
1. Normal after recharging unit.
1. Initial operation after recharging
may be noisy as refrigerant separates
2. Repair or replace motor.
3. Defective compressor mounts.
4. Defective compressor (internal
damage).
5. Refrigerant line vibrating.
5. Reposition and secure.
7. Foreign material in blower housing.
8. Duct work leaking or loose duct
(causing a whistle noise)
8. Repair and secure duct work
properly
9. Excessive water pressure on well,
(thumping noise).
10. Duct work Vibrating
9. Install 25 lbs. Pressure reducer on
well water supply line.
10. Install flex connectors on supply
1. System running in low speed.
1. No Action needed. This is normal
operation.
3. Dampers and/or registers closed.
3. Open dampers and/or registers.
4. Obstruction in system.
5. Clean or replace filters.