17
· The water should start circulang immediately. If
the motor works but if you do not noce water
circulaon within the first 15 seconds, the pump
may require priming due to trapped air (referred to
as an air lock’). If the pumps have not self-primed
aer 2 minutes, and water is not flowing from the
jets, DO NOT allow the pumps to connue to run.
Turn power off at the main house panel (or GFCI)
and try releasing the air by loosening the union on
the discharge side of the pump(s) while the motor
is not running. Turn the power back on. If the
pumps do not prime aer 15 seconds, somemes
momentarily turning the pump(s) off and on will
help the system to prime (note: do not do this
more than 5 mes). Repeat if necessary.
· Important: Under NO circumstances should the
pump(s) be allowed to operate without priming
beyond 5 minutes, as this may not only cause
unwarrantable damage to the pump, it may also
cause the control system to go into an overheat
condion.
· Turn the hydrotherapy pump(s) onto high speed
and re-check for leaks. The control system will
automacally return the pump to low speed aer
15 minutes.
· Adjust the hot tub heat control at the topside panel
to the desired water temperature.
· Adjust water balance (pH, TA, calcium hardness) to
recommended levels and add sanizer once the
water temperature reaches 20°C (68°F).
See secon HOT TUB WATER BALANCE
· Keep insulated safety hard cover on the hot tub,
and the air controls closed during the enre heat
up process.
NOTE:
In order to prevent damage to your pillows caused by
the gassing effect of the chemicals, we do recommend
to remove them when the spa is not in use.
By removing them you will extend considerably the
life length of your pillows. We do design ours pillows
to be removed easily in order to make sure they will
not remain in the spa when it’s not in use.
O RING / GASKET AT UNION CONNECTIONS
RELEASING AN AIR LOCK...
...THROUGH THE PUMP UNION