17
HYDROPOOL SERENITY SERIES CONTROL SYSTEMS NORTH AMERICA /
EUROPE GECKO IN.YE3
INITIAL START UP
Before applying voltage to power up your hot tub, it is
very important that you understand the sequence of
events that occur when the system is activated in order
that the pump(s) can be primed efficiently and damage
to the system can be avoided.
PROGRAM MENU
The program menu is accessible by holding down the
Light Key for 5 seconds. In the Program Menu, the
following parameters can be set: clock, filter or purge
cycles, economy mode and temperature units. While in
the program menu, use the Up and Down keys (or
Up/Down Key) to adjust the parameters and the Light
key to jump to the next parameter. The changes will be
saved after the confirmation of the last parameter only.
If there is no action taken for 10 seconds, the system
will exit the program menu without saving any changes.
SETTING THE CLOCK
Enter the program menu by holding down the Light key
for 5 seconds. The display will show the current clock
setting with the hour flashing. Use the arrow keys to
adjust the hour. Press the Light key to adjust the
minutes. Press the Light key to jump to the next
parameter or to the end of the parameters to save time.
TEMPERATURE CONTROL
FUNCTIONALITY AND
ADJUSTMENT
After you exit the programming mode your hot tub will
automatically heat to the factory preset default
temperature of 38oC (100oF).
The temperature shown on the screen is the current
water temperature. Use the UP and DOWN buttons to
set the desired temperature.
The set point icon will appear at the top of the screen.
After 3 seconds without any change to the set
temperature value, the keypad will resume the normal
display.
STANDBY MODE
Pressing the JET key for 5 seconds will enable the
Standby Mode. This mode allows you to stop all outputs
including automatic functions such as filter cycle, heat
request and smart winter mode for 30 minutes to
perform quick spa maintenance. When active, the
display will toggle between the “OFF” message, the
clock and water temperature.