» Separate cylinder halves.
» Remove the used O-rings between
the cylinder halves, in the base and
in the steam hose adapter.
» Clean the cylinder inside.
» Clean the strainer.
» Unscrew the hand nuts (A).
» Remove electrodes (B).
» Clean electrodes and check elec-
trode wear (s. „Changing electrodes“
section).
»
Check sensor electrode for salt
deposits and remove them if neces-
sary (
until metallically bright).
» Check the inside of the top part of
steam cylinder for crust build-up and
possible salt bridges (black grooves
between the electrode leads).
» Remove the deposits by scraping /
scrubbing them off.
» Replace the O-rings of the elec-
trodes.
» Install new electrodes (48). Make
sure that the electrodes are positio-
ned correctly (see exploded view).