Field Service Bulletin 27
HyPro2000 — HT2000 TORCH UPGRADE
Stainless steel
Air Plasma / Air Shield
130 A Cutting
Metric
English
Test Prefl ow
Flowrates
Test Cutfl ow
Flowrates
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce Height
Pierce Delay
Time
Prefl ow % Plasma % Shield (psi)
Air Air Air mm Volts mm mm/m mm factor % seconds
45 77 24
6 142 3.5 2625 7.0 200 0.3
10 149 4.1 1700 8.2 200 0.5
12 152 4.1 1380 8.2 200 0.8
15 160 4.4 900
Edge Start
20 165 4.6 430
Flow rates – lpm/scfh
Air Air
Preflow 26 / 56 68 / 145
Cutflow 44 / 93 68 / 145
Test Prefl ow
Flowrates
Test Cutfl ow
Flowrates
Material
Thickness
Arc
Voltage
Torch-to-Work
Distance
Cutting
Speed
Initial Pierce Height
Pierce Delay
Time
Prefl ow % Plasma % Shield (psi)
Air Air Air in Volts in ipm in factor % seconds
45 77 24
1/4 143 0.14 100 0.28 200 0.3
3/8 148 0.16 70 0.32 200 0.5
1/2 153 0.16 50 0.32 200 0.8
5/8 162 0.18 30
Edge Start
3/4 164 0.18 20
220536 220487220936
220935
(No IHS tab)
220488220892