15 HPT USER MANUAL
Please refer to EASTRON SDM630-Modbus V2 User manual for its connection and
baud rate settings.
6.3 Demand Responsive Modes(DRMs)
The inverter shall detect and initiate a response to all supported demand response
commands.
MODE DEMAND
DRM 0 Disconnect
DRM 1 No power consumption
DRM 2 Power consumption <50% rated power
DRM 3
Power consumption <75% rated power AND respond to reactive power when
capable
DRM 4 Increase power consumption (prior subject to constraints from other active DRMs)
DRM 5 No power generation
DRM 6 Power generation <50% rated power
DRM 7 Power generation <75% rated power AND sink reactive power if possible
DRM 8 Increase power generation (prior subject to constraints from other active DRMs)
DRMs Application Description
Only applicable to AS/NZS4777.2:2015.
• DRM0, DRM5, DRM6, DRM7, DRM8 are available.