EasyManua.ls Logo

Hytera RD98 Series - Interface Definition

Hytera RD98 Series
333 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Manual
79
8. Interface Definition
PA-Baseband (J105)
Pin No. Name Description
1 Pf_DET Forward power detection, ADC input
2 Temp_Protect_Volt Alarm voltage for temperature protection circuit
3 APC Output power setting, DAC output
4 VSWR_Protect_Volt Alarm voltage for the VSWR protection circuit
5 Final_Bias Bias voltage of final-stage PA, DAC output
6 GND
For grounding
7 Pr_DET Reverse power detection, ADC input
8 PA_Enable PA enable, TTL level, GPIO
9
RT1
Temperature detection signal, output by the
thermistor
10
RT2
Temperature detection signal, output by the
thermistor
Table 8-1 Interface between Baseband and PA
Exciter-Baseband (J101)
Pin No. Name Description
1 MOD_L
Modulation signal of reference crystal oscillator,
AC analog signal, from DAC
2 GND
For grounding
3 TX_PLL_CLK PLL data clock
4 GND
For grounding
5 GND
For grounding
6 TX_Control_FL Fast lock control (1: On; 0: Off)
7 TX_PLL_CS PLL data enable
8 TX_VCO_Watch
TX VCO watch, voltage sent back to MCU via
ADC

Other manuals for Hytera RD98 Series