EasyManua.ls Logo

HYTROL 190-ACC - User Manual

HYTROL 190-ACC
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Effective July 2015
(Supercedes July 2013)
Bulletin #682
190-LRS
190-ACC
190-LRC
190-LRSS
Installation
and
Maintenance
Manual
with Safety Information
and Parts List
RECOMMENDED SPARE PARTS HIGHLIGHTED IN GRAY
Model 190-ACC, LRC,
LRS & LRSS
Manual
de Instalación
y
Mantenimiento
con Información sobre Seguridad
y Lista de Refacciones
LAS REFACCIONES RECOMENDADAS SE RESALTAN EN GRIS
IMPORTANT!
DO NOT DESTROY
© COPYRIGHT 2009–HYTROL CONVEYOR CO., INC.
¡IMPORTANTE!
NO DESTRUIR
Hytrol Conveyor Co., Inc.
Jonesboro, Arkansas
PRESS OPTIMIZED FOR THE ENVIRONMENT
(IMPRESIÓN OPTIMIZADA PARA PROTEGER EL MEDIO AMBIENTE)

Table of Contents

Other manuals for HYTROL 190-ACC

Questions and Answers

  • L
    Lisa RomeroAug 17, 2025
    What to do if HYTROL 190-ACC Accessories conveyor will not start?
    • J
      Joshua ChaseAug 18, 2025
      If your HYTROL Accessories conveyor won't start or the motor frequently quits, the issue might be due to the motor being overloaded. Check for any overloading of the conveyor. Another cause could be that the motor is drawing too much current. In this case, inspect the heater or circuit breaker and replace it if necessary.
  • T
    Thomas Graham MDAug 20, 2025
    Why is my HYTROL 190-ACC Accessories motor overheating?
    • J
      James BrownAug 20, 2025
      If the motor or reducer in your HYTROL Accessories is overheating, several factors could be the cause. First, the conveyor might be overloaded; check its capacity and reduce the load to the recommended level. Excessive accumulation pressure can also lead to overheating. Low voltage to the motor may be a factor, so have an electrician check and correct it. Additionally, check the lubricant level in the reducer and relubricate it according to the manufacturer's recommendations. For a HYTROL reducer, refer to the separate manual. Finally, overly tight V-belts can cause overheating; reposition the take-up sheaves further from the double groove sheave.
  • A
    Andrew SpencerAug 22, 2025
    What to do if HYTROL 190-ACC Accessories belt slips?
    • I
      Isaiah OlsenAug 22, 2025
      If the belt on your HYTROL Accessories is slipping or won’t move but the drive is running, it could be due to several reasons. The conveyor might be overloaded, so check its capability and reduce the load if necessary. Alternatively, the belt might be too loose; try re-positioning the take-up sheaves closer to the double groove sheave. Too much pressure against the belt could also be the problem; in this case, loosen the spring tension on the pressure rollers.
  • B
    Brian WallaceAug 26, 2025
    How to fix loud grinding noise HYTROL Accessories?
    • L
      louismasonAug 26, 2025
      A loud popping or grinding noise in your HYTROL Accessories could stem from a few issues. It might be due to a defective bearing, in which case you should replace the bearing. Another possibility is loose set screws in the bearing; try tightening the set screws. A loose drive chain can also cause such noises, so ensure you tighten the chain.
  • N
    Nicole WalkerAug 27, 2025
    Why HYTROL 190-ACC drive chain wears quickly?
    • K
      Kimberly JonesAug 28, 2025
      Excessive wear on the drive chain and sprockets of your HYTROL Accessories can be attributed to a few causes. Lack of lubrication on the chain can lead to chain stretch, causing improper chain-to-sprocket mesh; in this case, replace the chain and sprockets and provide adequate lubrication. Note that if the problem reoccurs, a chain take-up may be required. Misalignment of the sprockets can also cause wear, so align the sprockets. Finally, a loose chain can contribute to wear, so make sure to tighten the chain.
  • T
    Travis MooreAug 30, 2025
    What to do if HYTROL Accessories tread rollers not turning?
    • B
      brownritaAug 30, 2025
      If the belt is moving but the tread rollers aren't turning on your HYTROL Accessories, it could be because there isn't enough pressure against the belt from the pressure rollers. Try tightening the spring tension on the pressure rollers in the area of the stalled rollers. Another cause could be a bolt in the suspension angle binding, preventing adjustment of the pressure rollers; loosen the bolt and adjust the spring tension as required, checking for burrs or foreign material behind the angles. Missing or broken springs or adjustment nuts can also be the cause, so replace and re-adjust them.
  • J
    James LutzSep 1, 2025
    Why is my HYTROL Industrial Equipment conveyor not starting or quitting frequently?
    • D
      davidhaleSep 1, 2025
      Your HYTROL Industrial Equipment conveyor might not be starting or could be quitting frequently due to the motor being overloaded. Check for overloading of the conveyor. Another cause could be the motor drawing too much current. In this case, check the heater or circuit breaker and replace it if necessary.
  • B
    Brad AndersonSep 4, 2025
    What to do if my HYTROL Industrial Equipment motor or reducer is overheating?
    • B
      Brandon FlynnSep 4, 2025
      If your HYTROL Industrial Equipment motor or reducer is overheating, it could be due to several reasons. The conveyor might be overloaded, so check its capacity and reduce the load to the recommended level. Also, the voltage to the motor could be low, so have an electrician check and correct as necessary. Other potential causes include low lubricant level in the reducer (relubricate per manufacturer’s recommendations; for HYTROL reducer, refer to separate manual) or one or more V-belts being too tight (re-position take-up sheaves further from double groove sheave).
  • S
    Sarah HamiltonSep 6, 2025
    What to do if HYTROL Industrial Equipment belt slips or won’t move, but drive runs?
    • K
      Karen JordanSep 6, 2025
      If the belt on your HYTROL Industrial Equipment is slipping or won’t move but the drive is running, it could be that the conveyor is overloaded. Check the capability of the conveyor and reduce the load to the recommended level. Another possibility is that the belt is too loose, so re-position the take-up sheaves closer to the double groove sheave.
  • B
    brandon89Sep 9, 2025
    Why does the drive chain and sprockets wear excessively on my HYTROL Industrial Equipment?
    • J
      Joyce EllisSep 9, 2025
      Excessive wear on the drive chain and sprockets of your HYTROL Industrial Equipment can be caused by a lack of lubrication on the chain, leading to chain stretch and improper chain-to-sprocket mesh. Replace the chain and sprockets and provide adequate lubrication. Note: If the problem reoccurs, a chain take-up may be required. Another cause could be sprockets that are out of alignment. Also, a loose chain can cause excessive wear, so tighten the chain.

HYTROL 190-ACC Specifications

General IconGeneral
BrandHYTROL
Model190-ACC
CategoryAccessories
LanguageEnglish