Highlights high torque and low-speed operation capabilities.
Focuses on stable operation under load changes via current suppression.
Describes flexibility in choosing between RS485 and analog signal control.
Emphasizes reduced cubic volume compared to older series.
Mentions the availability of an economical remote operator (DOP05).
Visual representations of inverter dimensions for different models.
Tabulated data on external and installation dimensions and weights.
Explains the function of various LEDs on the monitor section.
Step-by-step guide to setting the maximum operating frequency.
Instructions on how to start and control motor operation using the speed POT.
Guide on how to check the output current value displayed by the inverter.
Lists monitoring parameters and basic operational settings with function codes.
Details advanced functions and parameters, starting with code A01.
Covers additional advanced functions and parameters, starting with code b01.
Details advanced input/output and control functions, starting with code C01.
Describes protection against excessive output current exceeding rated limits.
Explains protection against motor overload via electronic thermal trip.
Details protection against high DC link voltage from regenerative energy.
Covers protection triggered by communication errors with the inverter.
Explains protection for low input voltage affecting control circuit operation.
Describes protection against short-circuits in the inverter output.
Indicates protection related to the Unattended Start Protection (USP) function.
Covers protection activated by errors within the inverter's EEPROM.
Explains protection triggered by external equipment fault signals.
Describes protection activated by main circuit temperature rise due to cooling fan failure.
Identifies main circuit terminals for power input, output, and grounding.
Details terminals for input signals, monitor signals, and frequency commands.
Explains the use of AC reactors for harmonic suppression and power quality.
Describes AC reactors for reducing motor pulsation and thermal relay issues.
Information on the economical remote operator for controlling the inverter.
Guidelines for operating general-purpose motors with the inverter.
Notes on using the inverter with special motor types like brake or explosion-proof.
Important drive-related operational notes including run/stop and emergency stop.