Configuration of the rear lights and brake lights
The rear lights and the stop, (typically two LEDs) are powered by the same output, the output is
modulated to obtain a low intensity for the tail lights, the parameter:
TailLightIntensity = 50; [1..50]%
Allows you to adjust the brightness of the rear lights, a lower value will decrease and vice versa a
highest increase.
Since braking output is modulated at 50% if you use a value very close to this for the sidelights the
braking effect will be barely visible.
The following parameter allows you to adjust the length of time of the brake lights stay lit when
you make a brake:
BrakeDuration = 500; [100..5000] mSec
The range of values allowed is from 100 to 5000 milliseconds.
Configuring the maximum current supplied to the motor
Parameter: CurrentMotorTreshold = 10; [1..15]
Adjusts the threshold of over current monitoring protection.
The default value is 10 Amperes, it is possible in case of use of particular reducers or very heavy
truck to increase up to a maximum of 15 Ampere the current supplied to the motor.
Configuration of the power supplied to the motor
The parameter: PowerMotorScale = 100; [1..100]%
Allows to adjust the overall power delivered to the engine during running, this function calibrates
accurately the movement speed to approach to the dynamics of the real truck, a lower value will
decrease and vice versa a higher increase.
Configuration of the vibration of the cab of the truck
The parameters: MinPwmMot = 25; [0..100] and MaxPwmMot = 30; [0 ... 100]
Allow to set the minimum and the maximum speed of the vibration unit, from 1% to 100%
To turn off simply enter the value 0 in both parameters.
Configuring the maximum reverse speed
The parameter: ReverseSpeed = 50; [1 ... 100]%
Used to limit the speed during reverse.