Important Information: Read This First! 4
Specifications 6
CareSens N Blood Glucose Monitoring System 7
Inserting or Replacing the Batteries 8
Caring for Your System 9
CareSens N Blood Glucose Test Strip 10
CareSens N Blood Glucose Meter 12
CareSens N Blood Glucose Meter Display 13
Preparation
Setting Up Your System 14
Adjusting the Date and Time 14
Setting the Sound On/OFF 17
Checking the System 18
Control Solution Testing 19
Comparing the Control Solution Test Results 21
Testing
Using the Lancing Device 22
Preparing the Lancing Device 23
Preparing the Meter and Test Strip 25
Flagging Post-meal Test Results 25
Applying Blood Sample 26
Discarding Used Lancets 28
Alternate Site Testing 29
HI and Lo Messages 32
Target Blood Glucose Ranges 33
Transferring Test Results 34
Additional Functions
Meter Memory 35
Viewing Averages Stored in the Memory 35
Viewing Test Results Stored in the Memory 37
Setting the Alarm Function 38
Setting the Post-meal Alarm (PP2 alarm) 38
Setting the Time Alarms (alarm 1-3) 39
Maintenance
Understanding Error Messages 41
General Troubleshooting 43
Performance Characteristics 44
Warranty Information 48
Table of Contents

Questions and Answers:

i-SENS GM505PAD Specifications

General IconGeneral
Brandi-SENS
ModelGM505PAD
CategoryBlood Glucose Meter
LanguageEnglish

Summary

Important Information

Safety Cautions

Warnings for safe operation and accurate results.

Battery Management

Inserting or Replacing Batteries

Step-by-step guide for safely inserting or replacing meter batteries.

System Setup and Configuration

Adjusting Date and Time

Guide to set the meter's clock, date, and time format.

Alarm Functions

Setting the PP2 Alarm

How to configure the post-meal alarm for 2 hours after setting.

Setting Time Alarms (alarm 1-3)

Guide to set up to three daily alarms with specific times.

System Checking and Calibration

Checking the System

Procedure to verify meter and strip functionality using control solution.

Control Solution Testing

Steps for performing a control solution test to ensure accuracy.

Control Solution Test Results

Test Preparation Steps

Preparing the Meter and Test Strip

Steps to insert the test strip and prepare the meter for testing.

Blood Sample Application

Obtaining Blood Sample

Steps to get a blood sample using the lancing device from the finger.

Applying Blood Sample to Strip

How to transfer the blood sample to the test strip for measurement.

Used Supply Disposal

Understanding Test Results

HI and Lo Messages

Explains high (HI) and low (Lo) glucose level indicators on the meter.

Reviewing Stored Test Results

Error Message Interpretation

Understanding Error Messages

Explains common error codes (Er1, Er2, Er3) and their solutions.

Troubleshooting and Error Resolution

Error Message Troubleshooting

Actions for specific error codes like Er4, Er5, Er6, Er8.

General Troubleshooting

Common problems and solutions for meter operation.