TW Calibraon Process
1. Turn the scale on.
2. Press the ‘cog’ to go into the Setup screen
3. Press Equipment Connecons
4. Press Load bars
5. Press the name of the load bar OR select create custom
6. Press ADVANCED
7. Press SPAN
8. Type in the max. weighing capacity of the load bars, e.g. 2000 Kg
9. Press Next
10. Enter a name for these load bars, e.g. the locaon where they are located
Example “Sheep System”
11. Press Next
12. Ensure that there is no test weight on the load bars
13. Press ZERO
14. Put test weight onto the load bars
15. Press WEIGH
16. Type in the amount of the test weight - Note 1: The test weight can be adjusted only to whole Kg
(or Lbs)
17. Press CONFIRM
18. Press SAVE
19. Test the weight at the entry end of the plaorm
20. Test the weight at the exit end of the plaorm
Please reference the Gallagher website for more informaon on
the TW Weigh Scale range
www.gallagher.eu/en_gb