At this point programming can be started for the four coee selections. When the desired quantity of coee is
obtained, press the selection once again and the dosing will stop. The same operation will have to be followed for
all buttons.
By carrying out this process all the groups will be programmed automatically.
NOTE: If we wish, we can operate in the same way for other groups, in order to set a customised dose for each
of the groups.
The selections that are already programmed will appear with their LEDs o. When this happens it is still possible
to modify the dose in the same manner as indicated above.
If the LED for the selection set is flashing during the programming of the dose, it means that the volume counter
is not sending a signal to the control unit, and at the end of the dosing the dose will be zero. Programming without
water. It is recommended that the flow meters be checked.
NOTE: If your model has a Display, you can see a screen indicating that it is in the programming menu.
Doses setting
Select withing 30s
NOTE: If your model has a touchscreen display, then it is possible to program the dose, by directly modifying the
volume of water through the display itself.
2.3.2. Programming the electronic pre-brew (not available on all models)
The control unit has a function called ‘pre-brew’. Pre-brew can be enabled or disabled. If your machine has a visual
display, it will be possible to carry out this action via an option on the display. If it does not have a display, the
function is performed in the following manner: