Workstation Plate
1 Power off the system.
See
Powering Off
the System
in
Chapter
3,
"Service Refer-
enced Procedures"
on
page 3-1.
2 Disconnect the power cord.
3 Remove the covers. See "Covers"
on
page 1-10.
4 Remove the access plate. See "Access
Plate"
on
page 1-2.
1-24 AS/400 940219404 Models 2xx Repair and Parts
5
If
you have a card enclosure installed,
remove the cards. See "Cards"
on
page 1-4.
6 Disconnect the workstation plate cable or
cables from the MFIOP.
7 Remove the workstation plate from the
frame by removing the screws.
8 Install the workstation plate by reversing
the removal procedure.
This
ends
the procedure.