Important:
Browser security features might prompt the user before it accepts the self-signed certicate that the
system issues.
It might be necessary to remove old certicates that are stored in the browser before the browser
accepts the request.
The web browser might display a warning about a potential security risk. It is safe to accept the risk and
continue.
After the technician port physical connection is completed (that is, connected both ends), it can take up
to 45 seconds before the port is fully up and able to process requests. Submitting requests before this
interval might result in 404 error responses.
If the http://service request in the browser causes a 404 error, or fails to produce a response, it
might be necessary to use the url https://192.168.0.1 in the browser request to connect to the
system.
If you are unable to connect to the system by using the technician port, you can use a monitor and
keyboard that are connected to the VGA and USB ports on the system to initialize the system. Complete
the following steps.
1. Access the command line by using the superuser credentials.
2. Issue the CLI command mkcluster -clusterip x.x.x.x -mask m.m.m.m -gw g.g.g.g -name name to
create the system.
Procedure
To initialize the system, complete the following steps.
1. Ensure that the system is powered on, as described in “Powering on the system” on page 68
.
2. Congure an Ethernet port on the personal computer to enable Dynamic Host Conguration Protocol
(DHCP) conguration of its IP address and DNS settings.
a) If you do not have DHCP, you must manually congure the personal computer. To do so, specify the
static IPv4 address 192.168.0.2, subnet mask 255.255.255.0, gateway 192.168.0.1, and
DNS 192.168.0.1.
3. Locate the Ethernet port that is labeled T on the rear of each node canister.
On FlashSystem 5010 systems, the second onboard 1 Gbps Ethernet port is initially used as the
technician port. Figure 69 on page 72 shows the location of the technician port ( T ) on a node
canister.
Figure 69. FlashSystem 5010 technician port
FlashSystem 5030 systems have a dedicated technician port. Figure 70 on page 73 shows the
location of the port ( T ) on a node canister.
72
IBM FlashSystem 5000 : FlashSystem 5000 Quick Installation Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM FlashSystem 5010 and is the answer not in the manual?

IBM FlashSystem 5010 Specifications

General IconGeneral
BrandIBM
ModelFlashSystem 5010
CategoryStorage
LanguageEnglish

Related product manuals