Removing the battery
CAUTION:
The battery contains lithium. To avoid possible explosion, do not burn or charge
the battery. Do not:
v Throw or immerse into water
v Heat to more than 100°C (212°F)
v Repair or disassemble
Exchange only with the IBM-approved part. Recycle or discard the battery as
instructed by local regulations. In the United States, IBM has a process for the
collection of this battery. For information, call 1-800-426-4333. Have the IBM part
number for the battery unit available when you call. (C003)
Local regulations may require removing the battery prior to disposing of or
recycling this product. Complete these steps to remove the battery.
1. Disconnect all power and communication cables.
2. Remove all transceivers.
3. Unscrew captive screws and remove the power supplies and fan assemblies.
4. Unscrew the fasteners and remove the sheetmetal cover.
5. On the circuit board, go to the B1 location (1 in Figure 15) and remove the
BR1225 battery from the holder.
6. Recycle the battery as appropriate.
Refer to the Environmental Notices and User Guide shipped with the product for
more information on battery recycling and disposal.