Physical and electrical specifications
Dimensions and weight:
Height: 43 mm (1.7 in)
Width: 429 mm (16.9 in)
Depth: 734 mm (28.9 in)
Weight:
Minimum configuration: 12.7 kg (28 lb)
Maximum configuration: 15.9 kg (35.1 lb)
Supported environment:
Air temperature
Server on: 5 °C to 40 °C (41 °F to 104 °F); altitude: 0 to 950 m (3,117 ft); decrease the maximum
system temperature by 1 °C for every 175-m increase in altitude.
Server off: 5 °C to 45 °C (41 °F to 113 °F)
Maximum altitude: 3,050 m (10,000 ft), 5 °C to 28 °C (41 °F to 82 °F)
Shipment: -40 °C to +60 °C (-40 °F to 140 °F)
Specific microprocessors:
Microprocessor Intel Xeon E5-2690, 135 W:
Temperature: 10 °C to 27 °C (50 °F to 80.6 °F)
Altitude: 0 to 304.8 m (1,000 ft)
Microprocessor models with 115 W and 130 W:
Temperature: 10 °C to 35 °C (50 °F to 95 °F)
Altitude: 0 to 914.4 m (3,000 ft)
Humidity
Server on: 8% to 85%, maximum dew point 24 °C, maximum rate of change 5 °C/hr
Server off: 8% to 85%, maximum dew point 27 °C
Design to ASHRAE Class A3, ambient of 36 °C to 40 °C (96.8 °F to 104 °F), with relaxed support:
Supports cloud like workload with no performance degradation acceptable (Turbo-Off).
Under no circumstance can any combination of worst case workload and configuration result in
system shutdown or design exposure at 40 °C.
Electrical
Models with 750 W power supplies:
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 8.9 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 4.5 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.14 kVA
Maximum configuration: 0.9 kVA
Models with 550 W power supplies:
100 to 127 (nominal) V ac; 50 Hz or 60 Hz; 6.5 A
200 to 240 (nominal) V ac; 50 Hz or 60 Hz; 3.3 A
Input kilovolt-amperes (kVA) (approximately):
Minimum configuration: 0.14 kVA
Maximum configuration: 0.66 kVA

Other manuals for IBM System x3550 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3550 M4 and is the answer not in the manual?

IBM System x3550 M4 Specifications

General IconGeneral
BrandIBM
ModelSystem x3550 M4
CategoryServer
LanguageEnglish

Related product manuals