FAULT IDENTIFICATION AND RECOMMENDED SOLUTIONS:
Fault: Possible cause: Remedy:
Check if the pump’s electrical plug is
correctly inserted into the socket.
Check fuses at home and any other
installation fuses which could have
disconnected the power supply from the
supply network.
Electricity supply failure
Check the electrical power supply in the
vicinity of your home- the electrical current
might have been disconnected by your
energy company for the whole area.
The pump does not
run. The panel does
not display any
information.
The pump is damaged. Contact the technical maintenance
department.
The parameters of the electrical supply
current are inadequate.
Check the parameters of the electrical
supply. If they are not adequate, contact the
relevant energy supplier.
The pump does not
run. The display
shows „- -„.
The bearings or the impeller are blocked
with impurities.
After disconnecting the power supply from
the pump, remove it from the installation
and remove any impurities.
There is air in the pump. Remove air from the system and vent the
pump.
Increase inlet pressure by adding the
heating medium to the installation.
The inlet pressure is too low.
Check the air quantity in the expansion
vessel.
The pump is noisy;
there is noise in the
installation. The panel
displays a number.
The pump performance is too high. Decrease the pressure on the suction side.
The pump is running
but provides
insufficient heat. The
panel displays a
number.
The pump operating parameters are too
low.
Increase the pressure on the suction side.
Run the pump in a higher operating mode.
CE DECLARATION OF CONFORMITY (Module A):
PHU DAMBAT
Gawartowa Wola 38, 05-085 KAMPINOS
Pursuant to the Conformity Assessment System Act of 30 August 2002 (Journal of Laws, Dz. U. from
2004, No. 204, item 2087) we declare under our sole responsibility that the series BETA pumps, to
which declaration relates, are in conformity with these following directives of the European Parliament
and the European Council, which apply to:
1) machines no. 98/37/EC (standards used PN-EN292-1:1991, PN-EN292-2-1991/A1:1995, PN-EN
809:1999/AC:2004)
2) electromagnetic compatibility no. 89/336/EEC (standards used PN-EN 55014-1:2004,
PN-EN 61000-3-2:2004)
3) electrical equipment designed to be used for selected voltage limits no. 73/23/EWG (used
standards PN-EN 60335-1:2004+ A1:2005+ A2:2008+ A12:2008, PN-EN 60335-2-51:2005)
Adam Jastrzębski
23.05.2010