EasyManua.ls Logo

Iceco JP30 - Page 11

Iceco JP30
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Do not expose the cooler to extreme heat.
Only use mild soap and water to clean the cooler.
Do not use a DC extension cord.
Do not use a power strip or two-way splitter.
Do not use power cord adapters of any kind other than those provided by the manufacturer.
Do not use ice cubes or fill the cooler with water. If ice does accumulate at the bottom of the cooler,
defrost the unit and use the drain plug to drain the water.
Do not modify the unit in any way.
Do not place hot materials (75 OFor higher) in the cooler. Allow materials to cool (50 OFor less) before
placing them inside the cooler.
Do not tip or store the cooler at an angle greater than 300 for extended periods. Compressor oil
contamination of the cooling system could occur.
Allow 2—4inches of space around the cooler at all times for proper ventilation of the cooling system.
The cooler must be secured at all times using straps or a mounting plate, especially in mobile
applications.
The power supply cable must be replaced only by qualified technical personnel and in any case by
an after sales service authorised by the Manufacturer.
ICECO is not liable in any way if you do not comply strictly with all the previsions in this manual.
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
FAULTS
Number
Error type
of flashes
E2
E4
Battery protection cut-out
(The voltage is outside the cut-out setting).
Fan over-current cut-out
(The fan loads the electronic unit with more than 1Apeak).
Motor start error
(The rotor is blocked or the differential pressure in the refrigeration system is too
high (>5 bar)).
Minimum motor speed error
(If the refrigeration system is too heavily loaded, the motor cannot maintain
minimum speed 1,850 rpm).
Thermal cut-out of electronic unit
(If the refrigeration system has been too heavily loaded, or if the ambient
temperature is high, the electronic unit will run too hot).