SERVICE MANUAL FD/HD
10
2.7. Electrical connection
It is mandatory to ground the equipment. To avoid possible electric shock on individuals or
damages to the equipment, the machine should be grounded pursuant local and/or national
regulations as the case may be.
The manufacturer shall be held harmless in case of damages arising due to the lack of the
ground installation.
In case the supply cable is damaged, it should be replaced by a cable of special assembly to be
furnished by the manufacturer or after-sales service. Such replacement should be performed by
qualified technical service only.
The machine should be places in such a way as to allow a minimum space between the back
and the wall to allow an easy access and without risks to the cable plug.
Safeguard the socket. It is convenient to install adequate switches and fuses.
Voltage is indicated in the nameplate and on the technical specifications section of this manual.
Variation on voltage above the 10% stated on the nameplate could result on damages or
prevent the machine start-up.
MODELS
VOLTAGE
FREQUENCY
PHASE
AMPS
TOTAL
FUSE
CABLE
(A)
(A)
ICE TECH FD/HD
215
220 / 50 HZ / 1F
14,5
15
3AWG14
5-20P
ICE TECH FD/HD
215
220 / 50 HZ / 1F
9
15
3AWG16
6-15P
ICE TECH FD/HD
415
220 / 50 HZ / 1F
10
15
3AWG16
6-15P