Set scan type (Priority or Normal scan) and scan resume timer
in advance, using Set mode.
q While pushing [H/L], push [DIAL•DW ] several times to
select the desired channel group (depending on the con-
nected transceiver’s version).
w Set TAG channels as described at previous item.
e Make sure the squelch is closed to start a scan.
r Push [SCAN•TAG] to start Pri-
ority or Normal scan.
•“
PPRRII--SSCCAANN 1166
”or “
NNOORRMMAALL
SSCCAANN
” appears during Priority
or Normal scan, respectively.
When a signal is detected, scan
pauses until the signal disap-
pears or resumes after pausing
5 sec. according to the Set mode
setting (Channel 16 is still moni-
tored during Priority scan).
Rotate [SELECTOR
DIAL
] to check the scanning TAG chan-
nels, to change the scanning direction or resume the scan
manually.
•“
1166
blinks at the channel comment indicator and a beep tone
sounds when a signal is received on Channel 16 during Prior-
ity scan.
t To stop the scan, repeat step r.
BUSYBUSY-25W25W------INTINT---CALL---CALL
LOCAL--DUPLOCAL--DUP
SCRAMSCRAM----TAGTAG
NORMALNORMAL-SCANSCAN
-34"34.206N34"34.206N
123"23.236W123"23.236W
----UTCUTC-10:10COMMERCIAL10:10COMMERCIAL
[DIAL][DIAL]
During normal scan
Appears
GRP
2 Monitor function
, Call channel programming
. Dualwatch/Tri-watch operation
0 Setting TAG channels
1 Starting a scan
The monitor function releases the noise squelch mute of the
microphone only. (An independent noise squelch system is
employed.)
Push
[VOL/SQL•MONI ]
for
1 sec. to activate the Monitor
function.
•“
BBUUSSYY
” blinks and audio is emit-
ted.
[VOL/SQL•MONI ] (or [ENT],
[CLR])
cancels the Monitor func-
tion
.
L
L
BUSYBUSY-25W25W------INTINT---CALL---CALL
LOCAL--DUPLOCAL--DUP
SCRAMSCRAM--TAG--TAG
NORMAL-SCANNORMAL-SCAN
-34"34.206N34"34.206N
123"23.236W123"23.236W
----UTCUTC-10:10COMMERCIAL10:10COMMERCIAL
[VOL][VOL]
Blinks
q While pushing [H/L], push
[DIAL•DW ] several times to
select the desired channel group
(depending on the connected
transceiver’s version) to be pro-
grammed.
w Push [16•C] for 1 sec. to select
call channel of the selected chan-
nel group.
•“
CCAALLLL
” and call channel number
appear.
e Push [16•C] again for 3 sec. (until
a long beep changes to 2 short
beeps) to enter the call channel
programming condition.
The channel number to be pro-
grammed blinks.
r Rotate [SELECTOR
DIAL
] to select
the desired channel.
t Push [16•C] to program the dis-
played channel as the call channel.
The channel number stops blinking.
Push [DIAL] to cancel.
-25W---INT---CALL
LOCAL--DUP
SCRAM--TAG
NORMAL-SCAN
-34"34.206N
123"23.236W
--UTC-10:10- INTL
[DIAL]
-25W---INT---CALL
LOCAL--DUP
SCRAM--TAG
NORMAL-SCAN
-34"34.206N
123"23.236W
--UTC-10:10- INTL
[DIAL]
-25W---INT---CALL
LOCAL--DUP
SCRAM--TAG
NORMAL-SCAN
-34"34.206N
123"23.236W
--UTC-10:10-CALLING
[DIAL]
-25W---INT---CALL
LOCAL--DUP
SCRAM--TAG
NORMAL-SCAN
-34"34.206N
123"23.236W
--UTC-10:10-CALLING
[DIAL]
GRP
-25W---INT---CALL
LOCAL--DUP
SCRAM--TAG
NORMAL-SCAN
-34"34.206N
123"23.236W
--UTC-10:10- VTS
[VOL]
q Select Dualwatch or Tri-watch in Set mode.
w Rotate [SELECTOR
DIAL
] after pushing [DIAL•DW ] to
select the desired channel.
While pushing [H/L], push [DIAL•DW ] several times to
select the channel group (depending on the connected trans-
ceiver’s version)
, if desired.
e Push [DIAL•DW ] for 1 sec.
to start Dualwatch or Tri-watch.
•“
DDUUAALL 1166
” appears during Du-
alwatch; “
TTRRII 1166
” appears
during Tri-watch.
•Abeep tone sounds when a sig-
nal is received on Channel 16.
•Tri-watch becomes Dualwatch
when receiving a signal on the
call channel.
r To cancel Dualwatch or Tri-watch, push [DIAL•DW ]
again.
GRP
GRP
BUSYBUSY-25W25W------INTINT---CALL---CALL
LOCAL--DUPLOCAL--DUP
SCRAMSCRAM--TAG--TAG
--------DUALDUAL-1616
-34"34.206N34"34.206N
123"23.236W123"23.236W
----UTCUTC-10:10COMMERCIAL10:10COMMERCIAL
[VOL][VOL]
Appears
GRP
GRP
q While pushing [H/L], push [DIAL•DW ] several times to
select the desired channel group (depending on the con-
nected transceiver’s version).
w Push [DIAL•DW ] then rotate [SELECTOR
DIAL
] to se-
lect the desired channel to be set as a TAG channel.
e Push [SCAN•TAG] for 1 sec. to set the displayed channel
as a TAG channel.
•“
TTAAGG
” appears in the display.
r To cancel the TAG channel setting, repeat step e.
•“
TTAAGG
” disappears.
Clearing (or setting) all tagged channels
While pushing [H/L], push [SCAN•TAG] for 3 sec. (until a long
beep changes to 2 short beeps) to clear all TAG channels in
the channel group.
Repeat above procedure to set all TAG channels.