TRANSMlTIER ADJUSTMENT (CONTINUED)
MEASUREMENT
ADJUSTMENT
ADJUSTMENT
ADJUSTMENT
CONDITIONS
VALUE
POINT
UNIT
LOCATION
UNIT
ADJUST
IdAPC
1
Displayed frequency:
3.50000 MHz
Rear Ammeter on the DC
22A
MAIN
R109
Mode
RnY
panel
power supply
[01
RF
POWER]
H
R95 (MAIN unit) : 3 o'clock position
R109 (MAIN unit): 3 o'clock position
R198 (MAIN unit): Max. clockwise
Ground CP6 with a jumperwire.
Transmitting
After adjustment, remove the jumper wire from CP6.
TRANSMIT 1
Displayed frequency:
14.10000 MHz
Rear
Connect an RF power
50W
MAIN
R511
TOTAL GAIN
Mode
USB
panel meter to [ANT
1]
[01 RF POWER]
:
H
connector.
[02
MIC GAIN]
5
Connect an audio generatorto [MIC]
connector and set as:
10
mV
/1.5
kHz
Transmitting
CARRIER
1
Displayed frequency:
14.10000 MHz
Rear Connect a spectrum
Minimum carrier MAIN Adjust
SUPPRESSION
Mode
USBandLSB
panel analyzer to [ANT
1]
via an level repeatedly
Apply no signal
to
[MIG] connector.
attenuator.
R191,
Transmitting
R193
OUTPUT 1
Displayed frequency:
14.10000 MHz
Rear Connect an
RF
power 100 W MAIN R95
POWER
Mode
:
USB
panel meter to [ANT 1]
[02
MIC GAIN]
5
connector.
Connect an audio generatorto [MIG]
connector and set as:
100 mV
/1.5
kHz
Transmitting
2
Displayed frequency :
52.00000 MHz
WOW
R98
3
Displayed frequency :
145.00000 MHz
Connect an RF power
10W
R338
meter to [ANT 2]
connector.
CWCARRIER
1
Displayed frequency:
14.10000 MHz
MAIN Connect an oscilloscope Adjust as follows:
MAIN
R198
LEVEL
Mode
CW
to CP3 and C177.
Keying (C171)
[01
RF
POWER]
H
I
:
[05
KEY SPEED)
: 60
CP3 :
[M4 BRK]
BK (semi break-in)
Transmit dots for a while using a paddle.
io-----:
.0
......
FMVCO
1
Displayed frequency:
29.10000 MHz
MAIN Connect a digital multi-
1.5V
MAIN C267
Mode
FM
meter to CP4.
[M4
TON]
OFF
[01
RF
POWER]
: H
Apply no signal to [MIG] connector.
Transmitting
FM
1
Displayed frequency:
29.10000 MHz
Rear
Connect an FM deviation
±4.8
kHz
MAIN R274
DEVIATION
Mode
FM
panel
meter to [ANT1] via an
[M4 TON]
:
OFF
attenuator.
[01 RF POWER]
H
[02
MIC GAIN]
5
R260 (MAIN unit): Center
Connect an audio generator to [MIG]
connector and set as:
300 mV
/1
kHz
Transmitting
2
Set the audio generator as:
±3.5
kHz
R260
10 mV
/1
kHz