Loading...
HF BANDS
OUTPUT
POWER
50 M BAND
OUTPUT
POWER
144 M BAND
OUTPUT
POWER
AM
CARRIER
AM
MODULATION
FM
DEVIATION
RESIDUAL
AM
SWR
DETECTOR
After adjustment, disconnect CP7 (CTRL unit) from GND.
5 - 6
TRANSMITTER ADJUSTMENTS—continued
ADJUSTMENT
ADJUSTMENT ADJUSTMENT CONDITION
MEASUREMENT
VALUE
POINT
UNIT LOCATION UNIT ADJUST
1
1
1
1
1
1
1
Displayed freq. : 14.10000 MHz
Mode : RTTY
[RF POWER] : Max. CW
[TUNER] : OFF
Transmitting
Displayed freq. : 51.00000 MHz
Mode : RTTY
[RF POWER] : Max. CW
[TUNER] : OFF
Transmitting
Displayed freq. : 145.00000 MHz
Mode : RTTY
[RF POWER] : Max. CW
[TUNER] : OFF
Transmitting
Displayed freq. : 14.10000 MHz
Mode : AM
[RF POWER] : Max. CW
[MIC GAIN] : Center
Apply no audio signals to [MIC]
connector.
Transmitting
Displayed freq. : 14.10000 MHz
Mode : AM
[MIC GAIN] : Center
[RF POWER] : Max. CCW
Connect an audio generator to
[MIC] connector and set as:
Frequency : 1 kHz
Level : 10 mVrms
Transmitting
Displayed freq. : 28.50000 MHz
Mode : FM
Tone : OFF
[RF POWER] : Max. CW
[MIC GAIN] : Center
Connect an audio generator to
[MIC] connector and set as:
Frequency : 1 kHz
Level : 10 mVrms
Transmitting
Displayed freq. : 145.00000 MHz
Mode : FM
Tone : OFF
[RF POWER] : Max. CW
[MIC GAIN] : Center
Connect an audio generator to
[MIC] connector and set as:
Frequency : 1 kHz
Level : 4.5 kHz deviation
at the connected
deviation meter.
Transmitting
Displayed freq. : 29.70000 MHz
Mode : FM
[RF POWER] : Max. CW
[TUNER] : OFF (Through)
Connect CP7 (SETI) on the CTRL
unit to GND.
Connect a 50 dummy load or an
RF power meter to [ANT1] connector.
Transmitting
Rear
panel
Rear
panel
Rear
panel
Rear
panel
Rear
panel
Rear
panel
Rear
panel
CTRL
Connect an RF
power meter to
[ANT1] connector.
Connect an RF
power meter to
[ANT1] connector.
Connect an RF
power meter to [ANT
144MHz] connector.
Connect an RF
power meter to [ANT
144MHz] connector.
Connect a modulation
analyzer to [ANT1]
connector through an
attenuator.
Connect an FM devi-
ation meter to [ANT1]
connector through an
attenuator.
Connect an FM devi-
ation meter to [ANT
144MHz] connector
through an attenua-
tor.
Connect a digital
multimeter or oscillo-
scope to the check
point CP1.
100 W
100 W
100 W
40 W
100% or less
4.5 kHz ±0.3 kHz
Minimum RESIDUAL
AM level
Minimum voltage
MAIN
MAIN
MAIN
MAIN
RF
CTRL
R306
R311
R317
R320
Verify
Verify
L252,
L251,
C3