Keyer Setup Menu 1
Set mode is used to set the CW side tone, memory keyer repeat time, dash weight, paddle
specifications, keyer type, etc.
1. Side Tone Level This item sets the CW side tone output level.
0 to 100% in 1% step can be selected.
2. Side Tone L-imt This item sets the CW side tone level limit. When the [AF] control is rotated
above a specified level, the CW side tone does not increase.
ON CW side tone level is limited. (default)
OFF CW side tone level is not limited.
3. Repeat Time When sending CW using the repeat timer, this item sets the time between
transmission.
1 to 60 sec. in 1 sec. step can be selected.
4. Dot/Dash Ratio This item sets the dot/dash ratio.
1:1:2.8 to 1:1:4.5 (in 0.12 step) can be selected.