PA Board
Driver idling current
- Set the mode to CW
- Open W29 leads, and connect current meter
- Transmit
- Adjust R11 for 100mA
- Close W29
Final idling current
- Set the mode to CW
- Open L8 side of R28 leads, and connect current meter
- Transmit
- Adjust R18 for 500mA
- Close R28
FAN
- Install multi-meter between J11-1 and ground
- Transmit
- Verify the voltage between 6V and 8V
- Receive
- Jumper between CP1 and CP2
- Verify the voltage for 12V