6 - 6
6-4 RECEIVE ADJUSTMENT
Select an adjustment item using [
] / [
] keys, then set to the specifi ed value using [
] / [
] keys on the connected PC’s keyboard.
ADJUSTMENT ADJUSTMENT CONDITION
MEASUREMENT
VALUE
UNIT LOCATION
RECEIVE
SENSITIVITY
[BPF (T1)]
[BPF (T2)]
NOTE:
“RECEIVE SENSITIVITY” must be adjusted before “S-METER.” Otherwise, “S-METER” will not be
adjusted properly.
1
• Channel : CH 1
[MIC/SP]
jack
Connect the SINAD meter
with an 8
load to the JIG
cable.
Minimum distortion
level
Connect the SSG to the antenna connector
and set as;
Frequency
Level
Modulation
Deviation
• Receiving
: 400.000 MHz [Low band]
450.000 MHz [High band]
: +20 dBµ
(–87 dBm)
: 1 kHz
: ±3.5 kHz
CONVENIENT:
The “RECEIVE SENSITIVITY” can be adjusted automatically.
1: Put the cursor on “BPF ALL and push [ENTER] key.
2: The connected PC tunes BPF’s to peak levels automaticaly.
S-METER
[RSSI]
1
• Channel : CH 1 Push the [ENTER] key on the connected PC’s keyboard to
set “S3” level.
Connect the SSG to the antenna connector
and set as;
Frequency
Level
Modulation
Deviation
• Receiving
: 400.000 MHz [Low]
450.000 MHz [High]
: +23 dBµ
(–84 dBm)
: 1 kHz
:
±
3.5 kHz
2
Set the SSG as;
Level
• Receiving
: –7 dBµ
(–114 dBm)
Push the [ENTER] key on the connected PC’s keyboard to
set “S1” level.
SQUELCH
[SQL]
1 • Channel : CH 4 External
speaker
Connect an 8
speaker to
the JIG cable.
Set the [SQL] to the
value that the audio
signals just appears.
• Close the squelch by adjusting the value of
[SQL] item on the CS-F3020 ADJ’s screen.
Connect the SSG to the antenna connector
and set as;
Frequency
Level
Modulation
Deviation
• Receiving
: 435.000 MHz [Low]
485.000 MHz [High]
: –14 dBµ
(–121 dBm)
: 1 kHz
:
±
3.5 kHz
†;
The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.