5 - 7
5-3 SOFTWARE ADJUSTMENT
Select an operation using [] / [] keys, then set specified value using [] / [] keys on the connected computer keyboard.
1
1
2
3
1
1
2
Operating freq. : 430.000 MHz [L]
480.000 MHz [ML]
490.000 MHz [MH]
512.000 MHz [H1]
520.000 MHz [H2]
Output power : Low1
Connect the RF power meter or 50
dummy load to the antenna connector.
Transmitting
Operating freq. : 400.000 MHz [L]
440.000 MHz [ML]
450.000 MHz [MH]
480.000 MHz [H]
Output power : High
Transmitting
Output power : Low2
Transmitting
Output power : Low1
Transmitting
Operating freq. : 415.000 MHz [L]
460.000 MHz [ML]
470.000 MHz [MH]
496.000 MHz [H1]
500.000 MHz [H2]
Output power : Low1
Set the FM deviation meter as:
HPF : OFF
LPF : 20 kHz
De-emphasis: OFF
Detector : (PP)/2
Push [P0] key while transmitting
Operating freq. : 400.000 MHz [L]
440.000 MHz [ML]
450.000 MHz [MH]
480.000 MHz [H]
Output power : Low1
IF bandwidth : Wide
Set the FM deviation meter as:
HPF : OFF
LPF : 20 kHz
De-emphasis: OFF
Detector : (PP)/2
Connect the audio generator to the multi
connector through the JIG cable (*OPC-
966) and set as: 1.0 kHz/150 mVrms
Transmitting
IF bandwidth : Narrow
Transmitting
REFERENCE
FREQUENCY
[TXF]
OUTPUT
POWER
[Power (Hi)]
[Power (L2)]
[Power (L1)]
MODULATION
BALLANCE
[Ballance]
FM
DEVIATION
[MOD W]
[MOD N]
Top
panel
Top
panel
Top
panel
Top
panel
Loosely couple a frequnecy
counter to the antenna connec-
tor.
Connect an RF power meter to
the antenna connector.
Connect an FM deviation meter
with an oscilloscope to the
antenna connector through an
attenuator.
Connect an FM deviation meter
to the antenna connector
through the attenuator.
430.0000 MHz [L]
480.0000 MHz [ML]
490.0000 MHz [MH]
512.0000 MHz [H1]
520.0000 MHz [H2]
4.0 W
2.0 W
1.0 W
±4.1 kHz A
±3.1 kHz B
±2.1 kHz
ADJUSTMENT ADJUSTMENT CONDITION
MEASUREMENT
VALUE
UNIT LOCATION
Set to flat wave
form
A: W/N version, B: M/N version

Related product manuals