33
4
BIIS OPERATION
Auto emergency transmission
When [Emergency Single (Silent)] or [Emergency Repeat (Silent)] is
pushed, an emergency signal is automatically transmitted for the
specified time period.
The status 22 (Emergency) is sent to the selected ID station, and
the position data is transmitted after the emergency signal when a
GPS receiver is connected to the transceiver.
The emergency transmission is performed on the emergency chan-
nel, however, when no emergency channel is specified, the signal is
transmitted on the previously selected channel.
There is no change in the function display or beep emission during
automatic emergency transmission.
Stun function
When the specified ID, set as a killer ID, is received, the stun func-
tion is activated.
When the killer ID is received, the transceiver switches to the pass-
code required condition. Entering of the passcode via the keypad is
necessary to operate the transceiver again in this case.