EasyManua.ls Logo

Iconix FX21 - Groups (Mob Files)

Iconix FX21
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FX21 User Manual V5.01+ 14Dec07 Page 7
GROUPS (MOB FILES)
A new record is stored (in permanent memory) in the selected group (mob file)
whenever WEIGH is pressed. A record consists of :
Tag Number (if used), Group, Condition Score (if used) and Weight.
In normal operation, before starting a new weighing session, a previously unused group
is selected from the range 1 – 99. At the end of the session, or at any time during, the
statistics for the group may be displayed or printed. Individual records for the selected
group may also be printed.
MEMORY CAPACITY: 7238 records in total for Version 4.01 onwards
3626 records in total for earlier versions
The version number of the FX21 is displayed at switch-on as ‘q5/12’ for example.
The memory capacity may be shared between the groups in any manner. i.e. any
number of groups may be used with any number of records in each, providing the total
number of records does not exceed 7238 (3626). See the section below USING “ALL
GROUPS” for how to check the total number of records that have been used.
When the record limit is reached, for a further press of WEIGH the message ‘GVMM’
will be displayed. No more records are able to be stored until some or all of the existing
records are cleared. Usually records from a previous weighing session (stored in
another group) can be cleared so that more records can be added to the currently
selected group.
DISPLAYING & SELECTING A GROUP
Press the key, then press *GROUP to display the selected group, for example ’HsQ
36’
where Group 25 is selected.
To continue putting records into this group, press the key again to return to the
normal operating mode.
Or, if a different group is required for the new weighing session, type the new group
number from the range 1 to 99, for example 3 9, to display
’HsQ 4:’.
To accept the new setting and return to the normal operating mode, press .
To see whether the selected group already has records in it, check the statistics for the
group using then *WGT STATS. See the STATISTICS section below.
USING “ALL GROUPS” (Group = 0)
Selecting ’HsQ 1’ allows access to all records in memory, regardless of which
groups individual records are stored in. The user may :
View global statistics. See the STATISTICS section below. Average weight, total
weight and the number of weighings etc. are the totals for all records in memory.
Note: The total number of weighings will show whether the memory capacity of the
FX21 will soon be reached (7238 or 3626 records, depending on version)
Delete all records in memory. See the section CLEARING RECORDS below.

Other manuals for Iconix FX21

Related product manuals