Table 11 Electrical Data
(F/G)9MVT TWO-STAGE, VARIABLE SPEED FURNACES
UNIT SIZE
0401410
0601714
0801716
0802120
1002120
1202422
UNIT SIZE
0401410
0601714
0801716
0802120
1002120
1202422
UNIT SIZE
0401410
0606014
0801716
0802120
1002120
1202422
VOLTS-
HERTZ-
PHASE
115-60-1
115-60-1
115-60-1
115-60-1
115-60-1
115-60-1
VOLTS-
HERTZ-
PHASE
115-60-1
115-60-1
115-60-1
115-60-1
115-60-1
115-60-1
VOLTS-
HERTZ-
PHASE
115-60-1
115-60-1
115-60-1
115-60-1
115-60-1
115-60-1
OPERATING
VOLTAGE
RANGE*
Max*
127
127
127
127
127
127
Min*
104
104
104
104
104
104
MAXIMUM
UNIT
AMPS
7.5
9.2
9.2
11.7
11.8
11.8
UNIT
AMPAClTY#
10.3
12.4
12.4
15.5
15.6
15.6
MINIMUM
WIRE
SIZE
AWG
14
14
14
12
12
12
(F/G)9MXT TWO-STAGE, ECM BLOWER FURNACES
OPERATING
VOLTAGE
RANGE*
Max* Min*
127 104
127 104
127 104
127 104
127
127
MAXIMUM
UNIT
AMPS
7.5
9.2
9.2
11.7
104 11.8
104 11.8
UNIT
AMPACITY#
10.3
12.4
12.4
15.5
15.6
15.6
MINIMUM
WIRE
SIZE
AWG
14
14
14
12
12
12
(F/G)9MXE SINGLE-STAGE, ECM BLOWER FURNACES
MAXIMUM
UNIT
AMPS
7.4
OPERATING
VOLTAGE
RANGE*
Max* Min*
127 104
1O4
1O4
1O4
1O4
1O4
9.1
9.1
11.6
11.7
11.7
127
127
127
127
127
* Permissible limits of the voltage range at which the unit operates satisfactorily.
UNIT
AMPACITY#
10.3
12.4
12.4
15.5
15.6
15.6
MINIMUM
WIRE
SIZE
AWG
14
14
14
12
12
12
MAXIMUM
WIRE
LENGTH
FT (M)$
36 (11.0)
29 (8.8)
29 (8.8)
37 (11.3)
36 (11.0)
36 (11.0)
MAXIMUM
WIRE
LENGTH
FT (M)$
36 (11.0)
29 (8.8)
29 (8.8)
37 (11.3)
36 (11.0)
36 (11.0)
MAXIMUM
WIRE
LENGTH
FT (M)$
36 (11.0)
30 (9.1)
30 (9.1)
37 (11.3)
36 (11.0)
36 (11.0)
MAXIMUM
FUSE OR CKT
BKR
AMPST
15
15
15
20
20
20
MAXIMUM
FUSE OR CKT
BKR
AMPST
15
15
15
20
20
20
MAXIMUM
FUSE OR CKT
BKR
AMPST
15
15
15
20
20
20
# Unit ampacity = 125percent of largestoperating component's full load amps plus 100 percent of allother potential operating components' (EAC, humidifier, etc.) full load
amps.
Time-delay type is recommended.
Length shown is as measured one way along wire path between unit and service panelfor maximum2 percent voltage drop.
Figure 39 1Isolation Relay for Humidifiers with Internal Power Supply
O
24 V
Coil
O
I
To HUM 24 VAC Terminal I
I
On Furnace Control Board
To Com/24V Screw Terminal
on Thermostat Strip
To Humidifier Leads
To Humidifier Leads
Al1157
34 Specifications subject to change without notice. 440 01 4001 04