421 03 9703 00 2/3/2015
Specifications subject to change without notice.
WIRING DIAGRAM MANUAL
Split System Air Conditioner
NH4A4
DANGER, WARNING, CAUTION, and
NOTE
The signal words DANGER, WARNING, CAU-
TION, and NOTE are used to identify levels of haz-
ard seriousness. The signal word DANGER is only
used on product labels to signify an immediate haz-
ard. The signal words WARNING, CAUTION, and
NOTE will be used on product labels and through-
out this manual and other manuals that may apply
to the product.
DANGER Immediate hazards which will result in
severe personal injury or death.
WARNING Hazards or unsafe practices which
could result in severe personal injury or death.
CAUTION Hazards or unsafe practices which
may result in minor personal injury or product or
property damage.
NOTE Used to highlight suggestions which will
result in enhanced installation, reliability, or opera-
tion.
Signal Words in Manuals
The signal word WARNING is used throughout this
manual in the following manner:
The signal word CAUTION is used throughout this
manual in the following manner:
Signal Words on Product Labeling
Signal words are used in combination with colors
and/or pictures on product labels.
WARNING
Safety Labeling and Signal Words
!
!
CAUTION
WARNING
TABLE OF CONTENTS
340086101 Wiring Diagram (1phase) 2..................
341422101 Wiring Diagram (3 phase) 3.................
MODELS
1 Phase
Wire Diagram
340086101
3 Phase
Wire Diagram
341422101
208/230160 208/230360
NH4A418AKA NH4A436AHA
NH4A424AKA NH4A448AHA
NH4A430AKA NH4A460AHA
NH4A436AKA 460360
NH4A448AKA NH4A436ALA
NH4A460AKA NH4A448ALA
NH4A460ALA
WARNING
!
DEATH, PERSONAL INJURY, AND/OR PROPERTY
DAMAGE HAZARD
Failure to carefully read and follow this warning
could result in equipment malfunction, property
damage, personal injury and/or death.
Installation or repairs made by unqualified per-
sons could result in equipment malfunction, prop-
erty damage, personal injury and/or death.
The information contained in this manual is in-
tended for use by a qualified service technician fa-
miliar with safety procedures and equipped with
the proper tools and test instruments.
Installation must conform with local building
codes and with the National Electrical Code
NFPA70 current edition or Canadian Electrical
Code Part 1 CSA C.22.1.
Question and Answer IconNeed help?

Do you have a question about the ICP NH4A4 Series and is the answer not in the manual?

ICP NH4A4 Series Specifications

General IconGeneral
BrandICP
ModelNH4A4 Series
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Labeling and Signal Words

DANGER, WARNING, CAUTION, and NOTE

Defines hazard levels and their meanings in manuals and labels.

Signal Words in Manuals

Explains the usage of signal words like WARNING and CAUTION within the manual.

Signal Words on Product Labeling

Describes the use of signal words combined with colors/pictures on product labels.

General Safety Warnings

DEATH, PERSONAL INJURY, AND/OR PROPERTY DAMAGE HAZARD

Outlines severe risks from improper installation or operation, and unqualified personnel.

1-Phase Wiring Diagram 340086-101

Connection Diagram

Illustrates the physical wiring connections for 1-phase split system air conditioners.

Schematic Diagram (Ladder Form)

Presents the logical circuit flow using a ladder diagram for 1-phase units.

Condensing Unit Charging Instructions

Cooling Only Charging Procedure

Provides a step-by-step guide for charging the unit during cooling operations using subcooling.

3-Phase Wiring Diagram 341422-101

Connection Diagram

Illustrates the physical wiring connections for 3-phase split system air conditioners.

Schematic Diagram (Ladder Form)

Presents the logical circuit flow using a ladder diagram for 3-phase units.

Condensing Unit Charging Instructions

Cooling Only Charging Procedure

Provides a step-by-step guide for charging the unit during cooling operations using subcooling.

Related product manuals