icos - Installation & Servicing
INSTALLATION
FLUE OUTLET
Note.
The template shows the positions of the fixing holes and
the flue hole centres for standard installation. If using
stand off kit option, refer to instructions in kit. Care MUST
be taken to ensure the correct holes are drilled.
1. Tape template into the selected position.
2. Ensure squareness by hanging a plumbline as shown. If
fitting a side flue extend the flue centre line onto the side
wall as shown.
3. Mark onto the wall the following:
a The 3 wall mounting plate screw positions (see
instructions on wall mounting template).
b. The position of the flue duct hole (see diagram below,
and template).
Note. Mark the centre of the hole as well as the
circumference
4. Remove the template from the wall.
16
WALL MOUNTING TEMPLATE
15
FLUE ASSEMBLY - Exploded View
LEGEND
1. Duct assembly.
2. Flue turret.
3. Turret gasket.
An optional flue duct extension kit is required for
wall thicknesses greater than :
Side 535mm (21")
Rear 638mm(25
1
/8").
V
Extended centre line
nm8257
137mm
Rear flue arrangement shown
nm8116
2
nm8165
202414-6.pmd 19/02/2008, 13:0717