shortedcondition.Theresistorsare
ratedto140+/-10%.Fusingcurrent
is1Aat125V.Fusingtimeis30-60ms
at125V,withoutcausingdangerous
conditions during opening of the fuse
element.Leadsneedtobereplaced
when fuse has opened.
NotethatTL-80andTL-82testleads
can only be specifically used with the
61-085and61-086testers.
Maintenance:
• Cleanthecasewithadampclothand
milddetergent.Donotuseabrasivesor
solvents.
Service, and Replacement Parts:
Forreplacementpartsortoinquireabout
service information contact
IDEALINDUSTRIES,INC.
Attn:RepairDept.
1000ParkAvenue
Sycamore,IL60178
TechnicalSupport:1-877-901-2005
or visit our website
www.testersandmeters.com.
Specifications:
VACRanges:120V,240V,480V,600VAC.
VACAccuracy:Relativeindicationonly
VDCRanges:120V,240V,600VDC
VDCAccuracy:Relativeindicationonly
Continuity(61-086only):ContinuousLED
andaudibleindicationatlessthan500kΩ
resistance.
Response time of 100ms.
Operating Frequency: 25-60Hz
InputImpedance:Low
OperatingEnvironment:32°Fto122°F
(<70%humidity)
Storage Temp.:-4°Fto140°F
(<80%humidity)
Altitude: 2000m
IndoorUse
Battery:(4)1.5V(IDEAL#61-201,IEC
#LR44,orNEOA#1166A).
BatteryLife: 200 hours typical.
Accessories included: TestLeads,(4)
1.5V“LR44”batteries,operatinginstructions
Dimensions:6.0”(H),2.3”(W),1.2”(D)
Weight: 8.0 oz
Safety:EN61010,CATIII600V
Double Insulation
Warranty Statement:
Thistesteriswarrantedtotheoriginal
purchaser against defects in material and
workmanship for two years from the date of
purchase.Duringthiswarrantyperiod,
IDEALINDUSTRIES,INC.will,atitsoption,
replace or repair the defective unit, subject
to verification of the defect or malfunction.
- 11 - - 12 -