EasyManua.ls Logo

IDEAL Esprit eco 24 - Page 42

IDEAL Esprit eco 24
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42
SERVICING
Esprit eco - Installation and Servicing
50
MAIN PCB REPLACEMENT
* Note. that production boiler PCB’s are
factory pre-set to operate for boiler range and
output, but when ordering Primary PCB as a
spare, an additional Boiler Chip Card (BCC)
MUST also be purchased for your specic
boiler range and output.
Note. Fit the earth strap provided with the
PCB to your wrist and secure to a suitable
earth on the boiler chassis.
1. Refer to Frame 40.
2. Note the control knob positions.
3. Remove the 2 screws retaining the control
box cover.
4. Carefully lift the cover at the front & pull
forward to remove.
3
6
5
5
Ribbon Cable Connection
Plastic
Clip
6
7
5. Unplug all lead connections to the PCB including the
ribbon cable.
6. Spring out the two side retaining clips and pull the PCB
upwards to clear the retaining posts.
7. Take the new Primary PCB and attach the appropriate
Boiler Chip Card (BCC) to it (this should correspond to
the output of the boiler: 24kW or 30kW).
Note. Ensure the correct orientation of BCC by placing
“TOP” side up as shown.
8. Re-connect all plug connections.
9. Reassemble in reverse order.
10. a. Turn power on
b. Displays “8” blue light on/off, “rst digit input”, “second
digit input”, “1st letter appliance type”, i.e. “2”, “4”, “c”
c. Move knob to required setting (standby, summer,
winter)
Note. If no BCC tted on non programmed board items a
& b will be displayed then “Boiler Type Card Fault - Contact
Installer” The correct BCC for this appliance will need to be
tted.
11. Check operation of the boiler. Refer to Frames 29 & 30.
SERVICING

Other manuals for IDEAL Esprit eco 24

Related product manuals