When replacing any part on this appliance use only spare parts that you can be assured
conform to the safety and performance specication that we require. Do not use
reconditioned or copy parts that have not been clearly authorised by Ideal.
24, 30, 35
May 2010 UIN 206104 A01
206104-1.pmd 26/05/2010, 16:011

Questions and Answers

  • S
    Sabrina JohnsonJul 30, 2025
    What to do if my IDEAL ESPRIT 2 24 Boiler display shows ‘HHHHH:::::AAAAA ’ (flashing)?
    • M
      Michael FisherJul 30, 2025
      If your IDEAL Boiler displays ‘HHHHH:::::AAAAA ’ (flashing) and isn't working for central heating or hot water, first check that the pressure gauge on the boiler shows at least 1 bar. If it doesn't, repressurize it to 1 bar using the filling loop. After doing so, turn off the tap on the filling loop, then switch the boiler off and back on to reset it. If you can't do this, or the pressure continues to drop, contact your installer. Also, check if all radiators have thermostatic radiator valves fitted; if they do, contact your installer.
  • J
    Jennifer GuerreroAug 4, 2025
    What to do if my IDEAL ESPRIT 2 24 Boiler displays ‘L : F ’ (flashing) and is not working?
    • G
      ggayAug 4, 2025
      If your IDEAL Boiler isn't working for central heating or hot water, but attempts to fire by going through 3 ignition attempts and the display shows ‘L : F ’ (flashing), try pressing the select (reset) button (C) for more than 3 seconds to repeat the ignition sequence. Also, check your gas supply by testing another appliance like a cooker or fire. If there's no gas supply, it's not a boiler fault, so contact your gas supplier. Finally, check the condensate pipe to ensure it's not blocked or frozen. Clear any blockage; if you can't, contact your installer.
  • D
    Dr. Kelsey RodriguezAug 8, 2025
    What to do if my IDEAL ESPRIT 2 24 Boiler display shows ‘L:A ’ (flashing)?
    • A
      amandabrownAug 8, 2025
      If your IDEAL Boiler isn't working for central heating or hot water and the display shows ‘L:A ’ (flashing), press the select (reset) button (C) for more than 3 seconds to try re-lighting the boiler. If the fault happens again, it indicates an overheat condition. Turn the boiler off and contact your installer. Also, check if all radiators have thermostatic radiator valves fitted; if they do, contact your installer.
  • M
    Michael TorresAug 12, 2025
    How to fix IDEAL ESPRIT 2 24 Boiler that will not fire for central heating?
    • R
      Robert WongAug 12, 2025
      If your IDEAL Boiler isn't working for central heating, and it's already set to an ‘ON’ period, check the programmer by setting it to permanent ON. If the boiler then fires, contact your installer to fix the programmer. Also, check the room thermostat by turning it fully up. If is not displayed on the user controls, contact your installer.
  • M
    Melanie MorganAug 16, 2025
    How to troubleshoot IDEAL ESPRIT 2 24 not working for heating or hot water?
    • K
      Katrina MillerAug 17, 2025
      If your IDEAL Boiler isn't working for central heating or hot water, check that the boiler has power by ensuring switch (A) is in the ON position and the time of day is displayed on the controls. Also, make sure the programmer is in an ON period or set to ON. If the time of day isn't displayed, it's not a boiler fault, so contact your installer or service company.
  • H
    Hannah VangAug 20, 2025
    Why does my IDEAL ESPRIT 2 24 Boiler come on for hot water without a tap being opened?
    • M
      Michael KeyAug 21, 2025
      If your IDEAL Boiler comes on for domestic hot water without a tap being opened and the display shows , check for dripping or dribbling taps or showers and ensure they are fully turned off. Also, check for leaks from the domestic hot water pipework, and if you find any, contact your installer.
  • R
    reyestinaAug 25, 2025
    Why does my IDEAL Boiler fire occasionally for about 2 minutes?
    • M
      Ms. Tammy PatrickAug 26, 2025
      This is a normal function of the IDEAL Boiler. During an ON period, the boiler periodically pre-heats the plate heat exchanger to optimize the delivery time for domestic hot water to taps or showers.

Summary

Safety and Installation Requirements

Gas Safety Regulations

Adherence to current Gas Safety regulations is mandatory for installation.

Electricity Supply

Details the necessary electrical supply and earthing for the appliance.

Important Safety Notes

Key precautions for safe operation and maintenance of the boiler.

Boiler Operation Modes

Boiler Controls and Safety Alerts

Critical Safety Warnings

Covers overheat, flame failure, pressure loss, condensate, and gas leak safety issues.

Troubleshooting Common Issues

Non-Product Fault Diagnosis

Lists common non-product faults and their corresponding solutions for user diagnosis.

iTime Programmer - Setting Day and Time

iTime Programmer - Setting Periods

iTime Programmer - Setting Temperatures

iTime Programmer - Fault Finding

Understanding and Resetting Faults

Explains symbols, fault codes (H/L), and how to reset the boiler after a fault.

iTime Programmer - Clearing Settings

iTime Programmer - Interface and Controls

IDEAL ESPRIT 2 24 Specifications

General IconGeneral
Boiler TypeCombi
MountingWall-mounted
TypeGas
Output24 kW
Central Heating Flow Temperature Range30°C - 80°C
Warranty2 years
Dimensions (H x W x D)700 x 395 x 278 mm