30
IDS 805 Installer Manual 700-266-02H Issued September 2009
LOCATIONS 82-83 Keypad Panic Reporting Code
This code will be reported if the panic button [P] on the keypad is pressed.
LOCATIONS 84-85 Keypad Tamper Reporting Code
The keypad tamper code will be reported if multiple attempts are made to disarm the panel using the
wrong user code. The code will be reported after 16 incorrect keystrokes i.e. four incorrect user codes.
LOCATIONS 86-101 Zone Reporting Codes
Locations
Reporting Code
86-87 Zone 1
88-89 Zone 2
90-91 Zone 3
92-93 Zone 4
94-95 Zone 5
96-97
Zone 6
98-99
Zone 7
100-101
Zone 8
Zone reporting codes will be reported if a violation of a zone causes an alarm condition. Various
conditions will apply as to when an alarm condition will be registered. These conditions are determined
by the zone characteristics as programmed into locations 1 to 8.
LOCATIONS 102-103
AC Fail Reporting Code
The AC fail will only be reported if the AC power is lost for a period longer than the delay programmed
into location 19.
LOCATIONS 104-105 AC Restoral Reporting Code
The AC restoral code will be reported if the AC power was lost for a period longer than the delay
programmed into location 19 and only after the AC power has been restored for the same period of time.
LOCATIONS 106-107 Siren Tamper Reporting Code
The siren tamper condition will be reported if the siren wire is open circuit or the fuse has blown.
LOCATION 108 Close & Away Reporting Code
The close code will be reported when the system is armed in the AWAY mode indicated by lit ARMED
and AWAY LED’s on the keypad.
NOTE:
The close code will not be reported if the system is armed in the STAY mode. The digit programmed into
this location is the first digit of the reporting code. The second digit will automatically be added and will
be the number which corresponds to the user code used to arm the system (See User Manual).
EXAMPLE:
If a close code of C (12) is programmed and the master user code is used to arm the system the 2 digit