IDS 805 Installer Manual 700-266-02H Issued September 2009
location 143, then an alarm condition will be registered. Program a value from [0] to [15]. A [0] will
disable the location. Please note that this only applies to Follower zones and Instant zones remain
instant.
LOCATION 143 Zone Trip Count Time Delay (Default = 0)
This time delay period applies to location 142. If the panel is armed and the number of violations
programmed into location 142 occurs within this time delay, an alarm condition will register. Program a
value from [0]
to [15]. Multiply the value of the entry by 10 seconds to calculate the delay time.
LOCATION 144 Programmable Trouble Display 1
Value Display of TLM Fail Display of Siren Tamper
0
1 
2 
3 Default
 
Enabled
Disabled
This location determines whether telephone line monitoring failure or siren tamper are displayed as
trouble conditions. Should the display be disabled no trouble condition will be shown i.e. the power LED
will not flash and no trouble condition shown when entering trouble-viewing mode. However, reporting
codes, if programmed, will be reported to the base station.
LOCATION 145 Programmable Trouble Display 2
Value
Display of Comms. Fail
Display of Keypad Tamper
Display of Eng. Reset
0
1 
2

3 

4

5 

6
 
7 Default 
 
Enabled
Disabled
This location determines whether Communication failure, keypad tamper, or engineers reset are
displayed as trouble conditions. Should the display be disabled no trouble condition will be shown i.e. the
power LED will not flash and no trouble condition shown when entering trouble-viewing mode. However,
reporting codes, if programmed, will be reported to the base station.