(This concerns the “CAREL” thermostat) Thermostat displays E0 or E1 or L0 or HI or EE or Ed or DF instead
of temperature:
E0 – temperature sensors inside the chamber are damaged – call authorized service
E1 – failure of evaporator sensor - call authorized service
L0 – low temperature alarm (lower than temperature range set within the device – call authorized service
HI – high temperature alarm – call authorized service
EE – internal defect of the regulator – call authorized service
Ed – max. defrosting time exceeded
DF – defrosting in progress (this is not an alarm signal)
Steam precipitation on glasses of the device is a normal phenomenon in case of high relative air
humidity exceeding 60% and does not require calling the service!
6.2. Service
IGLOO service telephone number: +48 (14) 662 19 56 or +48 605 606 071, e-mail: serwis@igloo.pl
If after checking points described in chapter 6.1 ”Fault identi cation and repair” the device still does not work pro-
perly, please contact Technical Service of the Igloo company, stating the data from the data plate Fig. 10 (p.16)
Serial number (NS)
• Production date
Type (name of the device)
and
Date when the device was purchased
Description of the problem
Your exact address
and telephone number (with the code number)
The above gure shows a demonstrative data
plate and the data stated on the plate are
exemplary data, which are not related with
“COSTA” refrigerating racks!
Fig.10 Data plate

Table of Contents

Related product manuals