operating parameter error
On first defrost ended correctly
MODIFYING THE PARAMETERS
Parameter navigation
The operating parameters, modifiable using the keypad, are divided into two types: frequent (type F) and
configuration (type C). Access to the latter is protected by password (default= 22) to prevent accidental or
unauthorized modifications.
Accessing the type F parameters:
- Press the SET button for more than 3 s (if there are active alarms, mute the buzzers). The display shows the
parameter code ‘PS’ (password);
- Use the UP and DOWN buttons to scroll the parameters. The LED corresponding to the category of parameters will
be on;
- Press SET to display the value associated with the parameter
- Increase or decrease the value using the UP or DOWN button respectively;
- Press SET to temporarily save the new value and display the parameter again;
- Repeat the procedure for any other parameters that need to be modified;
- Press the SET button for more than 3 s to permanently save the parameters and exit the parameter setting
procedure.
Table 3 Table of easy compact parameters for JSCRP and J2SCRP
probe measurement stability
select direct/reverse operation
night-time set point delta