Elements of device can corrode when improper used and maintenance. To avoid that please
follow the rules:
Do not allow contact of the surface of the device with substances containing chlorine and / or baking
soda in different varieties, which destroy the protective layer and components of the device (also
includes various stainless steel)
During maintenance services it is necessary to pay attention not to damage the data place of the device
Fig.10 (p.18), which contains signicant information for servicing organs and waste removal companies.
6. SERVICE
6.1. Fault identication and repair
In case of any difculties during actuation of the device or during its exploitation, please return to these chapters in this
manual, which explain the performed operation. This aims to ensure that the device is properly operated. If you still
experience difculties, the following hints will help you solve the problem.
The device is not working... – Make sure that:
The device is connected to the supply network
Voltage and frequency in the network are compliant with those recommended by the producer 230V/50Hz
The main switch is on
Thermostat is on (This concerns the Igloo thermostat If only two spots are visible on the display turn on the thermostat)
Water leakage from below the device or into the inside of the chamber:
Check whether the device is properly levelled
Check the patency of outow pipes
Empty the condenser tray or container
Check whether there is not too much ice in the rail and on the condenser defrost when necessary
The device is operating, but the lighting is off...– Make sure that:
Lighting switch is turned on
Fluorescent lamp or starting switch of the device are not burnt
The device does not reach the proper temperature, the lighting is on...– Make sure that:
Lighting switch is turned on
Temperature setting on the thermostat is properly set
Thermostat works properly
The condenser is clean, if necessary – clean the condenser
Ambient temperature does not exceed 25ºC
Enough time has passed for products to be cooled
Ventilation holes of the device are not blocked
(This concerns the “IGLOO” thermostat) thermostat displays C0 or C1 or C2 instead of displaying temperature:
This situation shall occur, when one of temperature regulation sensors has been destroyed.
The following messages may be displayed in such case:
C0 temperature sensors inside the chamber are damaged – call authorized service
C1 failure of evaporator sensor - call authorized service
C2 failure of condenser alarm sensors (or failure of second evaporator sensor) – call authorized service
(This concerns the “CAREL” thermostat) Thermostat displays E0 or E1 or L0 or HI or EE or Ed or DF instead of temperature:
E0 temperature sensor inside the chamber is damaged – call authorized service
E1 failure of evaporator sensor - call authorized service
L0 low temperature alarm (lower than temperature range set within the device – call authorized service
HI high temperature alarm – call authorized service
EE internal defect of the regulator – call authorized service
Ed max. defrosting time exceeded
DF defrosting in progress (this is not an alarm signal)
(This concerns the “IGLOO” thermostat) The device is working, sound signalling is activated...– Make sure that:
The condenser is clean, if necessary – clean the condenser
Condenser ventilator is working properly
Ambient temperature does not exceed 25ºC
The device is working too loud...– Make sure that:
The device is standing stably
Furniture adjoining the device do not vibrate when the cooling aggregate compressor is working