8 IP400, IP500 & IP600
A Service Contract for regular maintenance is recommended. Please contact IMC
Service Desk (01978 667743) for information.
FAULT FINDING
1 Pressing the green START button has no effect:
· Check that the key switch is switched on.
· Check the NORMAL/CONSTANT switch is set on normal.
· Check flap is fully closed.
· Check the truck is in the machine and fully latched in.
· Check electricity supply is on.
· Check the fuse in the plug.
· Check the electrical socket is functional.
2 The machine stops with the ram in the down position and RUN indicator
light on.
· Check that the machine NORMAL/CONSTANT switch is set on normal.
3 The machine stops during its cycle and RUN indicator light is not lit:
· Check flap is fully closed.
· Check that the truck is fully home and latched in.
· Under extreme load condition the compactor might overheat. The switchgear
contains an overload to prevent damage to the motor, this device will
automatically reset when cool. Wait a few minutes then press the START button
to reset and start the machine.
· Check electricity supply is on.
· Check the fuse in the plug.
· Check the electrical socket is functional.