Blacktip II - User Manual
IMENCO AS Visiting Address: Kophaug 3, 5570 Aksdal, Norway Office: +47 52 86 41 00 imenco@imenco.com
Org No: 923 005 749 MVA Postal Address: PO. Box 2143, 5504 Haugesund, Norway Fax: +47 52 86 41 01 www.imenco.com
9
4.3.2 Bipolar control:
Bipolar control gives no control of camera module settings.
Control voltage input ± 5vdc to ±24vdc, for pin numbering please refer to connector pin-
out in the QC document.
Autofocus on / off:
Controlled by applying control voltages over the focus pins and zoom pins
Manual focus:
Controlled by applying control voltage over the focus pins
Zoom control
Controlled by applying control voltage over the zoom pins
Figure 2 - Bipolar control signal matrix