- 6 -
5. Care and Maintenance
Transport When transporting the E60 always ensure that it is carried in
the original foam lined carry case.
Never transport the unit loose in your vehicle as the shock
and vibration will affect the accuracy and could knock it out
of calibration.
If the unit is to be transported overseas by sea or air it is
the operator’s responsibility to ensure the correct
procedures are adhered to for transporting batteries.
Storage Ensure the unit is stored within the recommended
temperatures of -10°C to +50°C After long periods of
storage check the charge of the batteries
Always clean the unit before storing. Even if the unit is in
regular use.
If the unit has been used in damp weather ensure it is dried
prior to placing it back in its carry case. It is important to
keep the carry case dry to prevent any ingress of moisture.
6 . Laser Specification
Operating Range 400m diameter with detector
Accuracy
±
3mm/30m
Self –levelling
± 5°
Rotation Speed 600 rpm
Laser 635nm Class 2
IP Rating
IP54
Power 4 x AA 1.5v Dry cell batteries
Working time Approx 20 hours
Working
-20°C - +45°C (-40°C - +70°C
Unit weight 1.5kgs
© Copyright Imex Group International 2018