6.2 Automatic functioning.
The CAR
V2
allows automatic functioning, in which a
program manages the room temperature during the hours
of the day.
e desired room temperature can be adjusted onto two
independent levels: comfort (
) and economy ( ) via the
button, whose distribution throughout the day or the
week is managed by hourly programming.
Press the button
until the icon switches-on on
the display .
e CAR
V2
is factory-set with a standard program stated in
the table that follows. If this should not satisfy requirements,
it is possible to modify it as described in the chapter relative
to programming.
Note: the system is designed to function on comfort and
economy temperature levels depending on the hour program
set. erefore also during functioning on economy level,
if the room temperature measured is below that set, the
boiler can ignite.
6.3 Forced automatic functioning.
If in automatic functioning mode (
) the room temperature
is modied by pressing the + / - buttons, the forced automatic
functioning mode is activated (displayed by the switch-on of
the ashing symbol). In this mode, the room temperature
will be regulated to the value set until the next switch-on or
switch-o phase of the automatic program set. e forced
automatic function can be interrupted by simply pressing
the button.
Days
16°C
20°C
Mon - Fri
(Day 1 - 5)
from 23 to 6
from 8 to 11
from 13 to 17
from 6 to 8
from 11 to 13
from 17 to 23
Sat - Sun
(Day 6 -7)
from 23 to 7
from 7 to 23

Table of Contents

Other manuals for Immergas CARV2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Immergas CARV2 and is the answer not in the manual?

Immergas CARV2 Specifications

General IconGeneral
BrandImmergas
ModelCARV2
CategoryTemperature Controller
LanguageEnglish