Page #29 background imageLoading...
Page #29 background image
29
- BUILD (dimension and building inertia), adjustable from
1 to 20, as per standard set on 10. It establishes the reaction
speed of the system depending on the type of system present.
For example:
Value System type
5 system with little heat inertia
10
system with normal dimensions with
radiators
20
system with a lot of heat inertia (e.g. oor-
standing system)
- AUTO A (self-learning), defines the activation of self-
learning, as per standard set at OFF. is function allows
the
CAR
V2
remote control to vary the oset, adapting it to
the room in which it is installed.
- S RH % (room humidity) enables the desired room hu-
midity to be adjusted during the cooling phase, which is
adjustable from 20 to 90 %, default value 60 %. is value
is adjustable only if a room humidity probe is present
(optional).
11.3 HOLIDY (holiday program).
From winter functioning mode it is possible to dene a number
of days (from 1 to 99) during which the system deactivates
both the hot water heating function and the room central
heating function.
e value is decreased every midnight in the day change. At the
end of the days set (the meter reaches 0) the previously active
functions are restored. e activation of the holiday function
is indicated by the ashing of the icon and the count of the
days remaining.
The holiday function can be deactivated by pressing the
button.
In the event of remote activation from telephone control, the
boiler is activated with the settings of the telephone control,
omitting the Holiday program.
N.B.: the room anti-freeze function is however guaranteed
also in holiday mode.

Table of Contents

Other manuals for Immergas CARV2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Immergas CARV2 and is the answer not in the manual?

Immergas CARV2 Specifications

General IconGeneral
BrandImmergas
ModelCARV2
CategoryTemperature Controller
LanguageEnglish