39
STMiN3E ed 09/11 MINI NIKE 3 E
Technical Documentation
Technical Documentation
e burner ignites.
No
e error 01 appears on the display
(wait for the P.C.B. to make 2 ignition cycles).
See error section 01 - b
No
e error 04 appears on the display
(wait for the P.C.B. to run 5 ignition cycle attempts).
See error section 04.
Yes
e burner stays on after the rst
10 seconds.
No
e error 01 appears on the display
(wait for the P.C.B. to run 2 ignition cycles).
See error section 01 -c
Yes
e error 27 appears on the display
Yes
See error section 27
e error 02 appears on the display
Yes
See error section 02 - b
e error 03 appears on the display
Yes
See error section 03 - b
No
The boiler reaches
and maintains the
set central heating
temperature.
No
Check the Maximum
heating output and
adjust it to maximum
if necessary.
See section D
Yes
e central heating request is satised.
The boiler reaches and
maintains the set DHW
temperature.
No
See section D
No
Check that,
- the ow rate of domestic hot water is
not greater than the amount the boiler
is able to supply (see technical data,
output, ow rate, ∆T);
- the plate heat exchanger is clean and
replace it, if necessary.
Yes
e domestic hot water request is satised.